National Repository of Grey Literature 5 records found  Search took 0.01 seconds. 
Averaging of biological signals
Němeček, Tomáš ; Vítek, Martin (referee) ; Smital, Lukáš (advisor)
The main objectives of this thesis are to study theory of signal averaging, filtered residue method and methods of stretching/shrinking signal. It will also test the functionality of those methods. Thesis contains theoretical analysis, explanation of principles and testing of behaving of used methods.
Averaging of biological signals
Kubík, Adam ; Čmiel, Vratislav (referee) ; Smital, Lukáš (advisor)
The main aim of this thesis is to introduce issue of averaging of biological signals. The first part of the thesis deals with the principles of individual averaging methods (constant, floating and exponential window) and describes their basic features. Moreover, the principle of filtered residue, detection of QRS complex, and stretching/shrinking the length of RR-interval to the standardized length are explicated. In the second part of the thesis the outcomes of practically realized (Matlab and GUI) methods of averaging (by final signal-to-noise ratio) are evaluated. Signals from MIT-BIH database are used.
Averaging of biological signals
Němeček, Tomáš ; Vítek, Martin (referee) ; Smital, Lukáš (advisor)
The main objectives of this thesis are to study theory of signal averaging, filtered residue method and methods of stretching/shrinking signal. It will also test the functionality of those methods. Thesis contains theoretical analysis, explanation of principles and testing of behaving of used methods.
Averaging of biological signals
Kubík, Adam ; Čmiel, Vratislav (referee) ; Smital, Lukáš (advisor)
The main aim of this thesis is to introduce issue of averaging of biological signals. The first part of the thesis deals with the principles of individual averaging methods (constant, floating and exponential window) and describes their basic features. Moreover, the principle of filtered residue, detection of QRS complex, and stretching/shrinking the length of RR-interval to the standardized length are explicated. In the second part of the thesis the outcomes of practically realized (Matlab and GUI) methods of averaging (by final signal-to-noise ratio) are evaluated. Signals from MIT-BIH database are used.
Vyhodnocení ERD/ERS: vyhodnocení latence pomocí plovoucího okna
Chládek, Jan ; Nestrašil, I. ; Jurák, Pavel ; Halámek, Josef ; Bareš, M. ; Rektor, I.
Event Related Synchronization/Desynchronization is among others characterized by amplitude and latency. Latency determination depends on the type of evaluation method and its parameters. Therefore its detection can be multiple-valued. To avoid the incorrect latency detection the analysis using smoothing floating window with different widths was employed

Interested in being notified about new results for this query?
Subscribe to the RSS feed.